1、全球实现300KHZ超高频率 频率越高,X射线的纹波系数越低,X射线剂量控制越精确,发射出的软射线越少,对人体的伤害越低,成像质量也大幅上升。
2、全球实现数字化、智能化操控设计 Poskom发生器采用先进的计算机处理技术,Poskom设备开机自检只需1分钟即可完成,而其他厂家设备都需要5分钟以上。
3、全球实现功率器件模块化设计 模块化设计的设备可以保障医院在机器发生故障时依然能照常使用直到维修完毕,改变了以往X射线发生器一旦发生故障医院就无法工作的历史。
4、全球率先实现固态发生器冷却技术固态发生器冷却技术一般只应用在更高端的设备上,而Poskom率先在普通X光机上普及了此项高端技术,从此避免了因为高压冷却油箱漏油导致发生器故障的发生。
HIGH FREQUENCY X-RAY GENERATORS
X线高压发生器
'100423
PXR-321B~501B
PXR-502B
PXR-501T
PXR-502T
Power Rating
32~50kW
50kW
50kW
50kW
Type
R
R/F
R
R/F
Radiography kV
40 - 125/150 kV
40 - 150 kV
40 - 150 kV
40 - 150 kV
Fluoroscopic kV
40 - 125 kV
40 - 125 kV
kV Accuracy
±5%+1 kV
±5%+1 kV
±5%+1 kV
±5%+1 kV
mA Range
10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125,160, 200, 250, 320, 400(32kW), 500(40kW), 630(50kW)
10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125,160, 200, 250, 320, 400, 500, 630
10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125,160, 200, 250, 320, 400, 500, 630, (800)
10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125,160, 200, 250, 320, 400, 500, 630, (800)
mA Accuracy
±5%+1 mA
±5%+1 mA
±5%+1 mA
±5%+1 mA
Fluoroscopic co
ntinuous mode mA
0.1 to 4mA , 1mA step
0.1 to 4mA , 1mA step
Time Range
1ms to 10sec
1ms to 10sec
1ms to 10sec
1ms to 10sec
mAs Range
0.1 to 500/630 mAs
0.1 to 630 mAs
0.1 to 630 mAs
0.1 to 630 mAs
APR
216
256
216
256
AEC
Optional
Optional
Optional
Optional
High speed starter
Optional
Optional
Buckies
2 Unit Standard
Standard 2/Option 2
Standard 2
Standard 2/Option 2
Rotor Supply
Low Speed Standard
Low Speed Standard
Low Speed Standard
Low Speed Standard
# of X-ray Tube
1 Tube Standard
2 Tube Standard
2 Tube Standard
2 Tube Standard
ABC
Optional
Optional
Line power
200V/220/240 V , 1 φ
200V/220/240 V , 1 φ
380/400/440/480V, 3φ
380/400/440/480V, 3φ
Automatic Line Compensation
±10%
±10%
±10%
±10%
C-arm
高压发生器
C-650
HTC-35
(High tension C-Arm)
HTC-120
(High tension C-Arm)
Power Rating
2.0kW
3.5kW
12kW
Radiography kV
40 - 110 kV
40 - 110 kV
40 - 125 kV
kV Accuracy
±5%+1 kV
±5%+1 kV
±5%+1 kV
mA Range (Fluoroscopic)
0.1mA to 5mA
0.1mA to 5mA
0.1mA to 10mA
mA Range
(Radiography)
20mA
20mA to 40mA
20mA to 150mA
mA Accuracy
±5%+1 mA
±5%+1 mA
±5%+1 mA
Output Time
0 to 5 min
0 to 5 min
0 to 5 min
Rotor Supply
Low Speed Standard
# of X-ray Tube
Toshiba DF-151SBR
Toshiba DF-151SBR
1 Tube Standard
Line power
100V/110/120 V , 1 φ
200V/220/240 V , 1 φ
200V/220/240 V , 1 φ
Automatic Line Compensation
±10%
±10%
±10%
别的类型
高压发生器
POX-100BT
(Mobile System)
PXM-150(Mobile)
HT-200(Mammography)
Power Rating
5.0kW
15kW
3.5kW
Radiography kV
40 - 110 kV
40 - 125 kV
22 - 49 kV
kV Accuracy
±5%+1 kV
±5%+1 kV
±5%+1 kV
mA Range
20mA to 100mA
50mA to 300mA
10mA to 100mA
mA Accuracy
±5%+1 mA
±5%+1 mA
±5%+1 mA
mAs Range
0.1 to 100 mAs
0.3 to 320 mAs
0.3 to 200 mAs
Rotor Supply
Low Speed Standard
# of X-ray Tube
OX/110-15
1 Tube Standard
1 Tube Standard
Battery Charger
Line power
200V/220/240 V , 1 φ
200V/220/240 V , 1 φ
200V/220/240 V , 1 φ
Automatic Line Compensation
±10%
±10%
±10%